Patient Monitor HD-11V

Patient Monitor HD-11V

The Patient Monitor HD-11V is a versatile, high-performance device designed to monitor patient vital signs in real-time across various medical settings. Featuring an intuitive interface, the HD-11V tracks critical parameters like heart rate, blood pressure, SpO2, and respiratory rate. It offers a high-resolution display, customizable alarms, and advanced data storage capabilities. With built-in connectivity, the monitor integrates easily into hospital information systems for seamless data sharing. The HD-11V is ideal for use in intensive care units, emergency departments, and operating rooms, delivering reliable, continuous monitoring to enhance patient safety and care quality.

  • 12.1 inch, 800*600/1024×768 dpi, color TFT display:
  • Suitable for OT and ICU:
  • Separated module: Main board+Parameter module(ECG, NIBP, SpO2);
  • Display brightness adjustable;
  • Real time S-T segment analysis, and ARR analysis;
  • SpO2 Pitch Tone Variation and Drug Dose Calculation;
  • Parameter waveform and characters color selectable
  • Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
  • Standby mode for power saving and suspend monitoring.
  • 7-lead ECG waveforms display in phase,
  • Capture dynamic waveforms and history waveforms review,
  • VGA output:
  • Built-in rechargeable lithium battery 4 hours, and battery volume checking, Efficient resistance to interference of defibrillator and HF knife;
  • SD card memory and USB data output:
  • TCP/IP networking platform enable abundant future upgrade& CMS;
  • Complete and flexible mounting solution for transportation and
  • In-patient monitoring.

SPECIFICATIONS:

ECG:

  • Lead mode: 5-lead(R,L,F,N,C)
  • Lead selection: I,II,III,avR, avl,avF,V
  • Waveform: 3 and 7 channel selectable
  • Gain selection: 0.5mm/mv,1mm/mv,2mm/mv
  • Sweep speed: 12.5mm/s;25mm/s;50mm/s

Heart rate range:

Adult: 15~300bpm;

Neonate/Pediatric:15-350bpm

  • Accuracy: +1bpm or +1%, whichecer is greater
  • Resolution: 1bpm
  • Filter: surgery mode:1~20Hz
  • monitor model: 0.5~40Hz
  • Diagnostic mode: 0.05~130Hz
  • Scaling signal: 1mv,+3%
  • Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
  • Alarm range: 15~350bpm

SPO2

  • Measurement range: 0~100%
  • Resolution: 1%
  • Accuracy: +2%(70-100%);0-69% unspecified
  • Alarm range: 0~100%
  • Pluse Rate: range:20~300bpm
  • Resolution: 1bpm
  • Error: +1bpm or +2%, whichever is greater

RESP:

  • Method: Thoracic impedance
  • Measurement range: Adult:7~120rpm;
  • Neonate/Pediatric:
  • 7~150rpm
  • Apnea alarm: YES,10~40s
  • Resolution: 1rpm
  • Accuracy: +2rpm

TEMP:

  • Compatible probe: YSI or CYF
  • Measurement range: 5~50°C
  • Resolution: 0.1°C
  • Accuracy: +0.1°C
  • Refreshing time: about 1
  • Average measuring time: <10s

NIBP:

  • Method: Digital Automatic oscillometric
  • Operation mode: Manual/Automatic/continuous
  • Auto measurement time: Adjustable(1~480min)
  • Measurement Unit: mmHg/Kpa selectable
  • Measurement types: Systolic, Diastolic, Mean

Measurement tange:

  • Range of Systolic pressure:
  • Adult: 40-270mmHg
  • Pediatric: 40~220mmHg
  • Neonate: 40~135mmHg
  • Range of mean pressure:
  • Adult: 20~235mmHg
  • Pediatric: 20-165mmHg
  • Neonate: 20~110mmHg

Range of diastolic pressure:

  • Adult: 10~215mmHg
  • Pediatric: 10~150mmHg
  • Neonate:10~100mmHg

Over-pressure protection:

  • Double safety protection
  • Resolution: 1 mmHg
  • Alarm: Systolic.Diastolic, Mean
  • IBP (Optional)
  • IBP Waveform: 2-Channel
  • Max 8 channels
  • Measurement Range: -50-350mmHg
  • Resolution: 1mmHg:
  • Unit: mmHg, kPa

Accuracy:

  • Static:±1mmHg or 2%, whichever is greater
  • (exclusive of transducer)
  • Dynamc: ±4mmHg or 4%, whichever is greater
  • Sensitivity of transducer: 5 uV/V/mmHg, ±2%
  • Impedance of transducer:300-3000 Ohm

Transducer sites:

  • ART, PA, LAP, RAP,CVP, ICP,P1,P2
  • Selection of measurement range:
  • ART: 0~+350mmHg
  • PA:-10~+120mmHg
  • CVP/RAP/LAP/ICP:-10~+40mmHg
  • P1/P2:-50+360mmHg

EtCO2( Sidertream CO2, Optional)

  • Measurement range: 0~99mmHg
  • Accuracy: +2mmHg (0~40mmHg)
  • Sampling Range: 100ml/min
  • Sampling rate accuracy: 15%
  • Respiration rate: 0~120rmp
  • Respiration accuracy: +2rmp (0~70rmp)
  • +5rmp (>70rmp)
  • Respiration time: 240msec (10% to 90%)
  • Delay time: <25

EtCO2 (Mainstreaam CO2, Optional)

  • Method: Infrared Spectrum
  • Range: 0.0-10% (0~76%)
  • Resolution: 1mmHg (0.1%)
  • Accuracy: <5%(±4.0 mmHg)
  • Or 10% (of Readings)

Suntech(Suntech):

  • Technique: Oscillometric
  • Patient Applications: Adult Pediatric, Neonate
  • Systolic Range: 40-265mmHh
  • Diatolic Range: 20-200mmHh
  • MAP Range: 27-222mmHh
  • Pulse Range: 25-300BPM
  • Transducer Accuracy: ±3mHg up to full range
  • Operation Conditions:
  • 0°C to 50°C, 15% to 95% non-condensing RH
  • Storage Conditions:
  • -20°C to 65 °C, 15%to 95% non-condensing RH

Recorder (Optional)

  • Build-in, thermal array
  • Plethysmogram caveform: 2 channels
  • Record mode: manual, on alarm, time-defined
  • Recording width: 50mm
  • Printing speed: 50mm/s
  • Recording type: Frozen waveform record
  • NIBP recall record
  • Trend table record
  • Alarm record
  • Fixed-time record